ASTM E1264 PDF

This standard is issued under the fixed designation E ; the number immediately 1 This classification is under the jurisdiction of ASTM Committee E on. Find the most up-to-date version of ASTM E at Engineering Standard Classification for Acoustical Ceiling Products. Status: Withdrawn · Replaced by: ASTM E Buy this standard. Price: SEK. PDF. Add to cart.

Author: Vura Fenriramar
Country: Guinea-Bissau
Language: English (Spanish)
Genre: Environment
Published (Last): 12 March 2008
Pages: 182
PDF File Size: 5.67 Mb
ePub File Size: 17.19 Mb
ISBN: 146-7-48309-144-2
Downloads: 29196
Price: Free* [*Free Regsitration Required]
Uploader: Tedal

The progress of the flame front across the test material is measured by visual observation, while the smoke emitted is measured as a factor of optical density. These time classes could be from 15 up to minutes in steps defined in the classification standard EN This could e126 the case in a room which has just a small amount of combustible furnishings and is equipped with surface linings that make just a negligible contribution to the fire development.

E Classification for Determination of Articulation Class. UL fire-rated ceiling assemblies may be required by building code.

During the growth phase the fire increases in size and other objects around the fire origin asm begin to burn. The heat radiation from the layer of fire gases is so great at this stage that it causes all combustible materials to ignite. Never miss a beat. Case Studies Looking for reference examples or a gallery of ceiling images? Testing requires 24 feet of material to be exposed to a flame ignition source in a Steiner Tunnel Test to determine how far the fire will spread during 10 minutes, and how much smoke is developed during this astj.

They do not rot nor corrode. Euroclasses according to classification standard EN Fire classification of construction products and building elements – Part 1 Classification using test data from reaction to fire tests. The classes are always combined with a time class expressed in minutes. There were no books found for the applied asstm filters.

Standard Classification for Acoustical Ceiling Products

Every second counts once a fire has started. Asstm incipient phase or beginning of a fire is dependent on the size of the ignition source and the properties of the materials and objects that are directly affected. Grid Suspension Systems Our Chicago Metallic acoustical grid systems offer a wide range of high performance suspenion system solutions.

  EVOLUTION EIN KRITISCHES LEHRBUCH PDF

The core material is non-combustible. They must not break and collapse during the early stages of e12644 fire when evacuation and rescue operations can still be carried out. Visit our case study library.

ASTM E – 14 – Standard Classification for Acoustical Ceiling Products

Standards can be on either a national base e. Both use an arbitrary scale base on an asbestos-cement board having a value of 0, and red oak wood having a value of Demonstrating fire resistance, acoustic ceiling panels and tiles are required to be tested for surface burning characteristics.

F Standard Specification for Driven Fasteners: The test was developed by Al Steiner of UL and has been ashm as a reference into North American standards for materials testing. To pass this requirement a ceiling system should be able to withstand a heat exposure of approx. The main purpose of the fire safety design of a building is to minimise the consequences of a fire. A smoke production index and flame spread index is then derived from the measurements that are taken.

The fire safety demands on suspended ceilings can vary depending on both the type of room and building where they are to be installed. Building elements classified as “fire resistant” with respect to integrity and insulation are used as a means to prevent fire being spread between fire compartments. With virtually no organic content, they aztm naturally resistant toward mold, mildew and microorganisms.

Normally reaction to fire tests are carried out in small or intermediate scale. In the growth phase the fire is local.

ASTM E1264 – 14

The interior surfaces are covered with the test material and a burner is applied at one end of the tunnel. Enter your account email address satm request a password reset: The classes for flaming droplets and particles are d0, d1 and d2, where d0 is the asmt.

Our stone wool ceiling panels do not warp, curl or cup. The temperature in the test furnace follows the so-called “standard fire curve” which is designed to represent a fully developed fire.

  JUMO PAPERLESS RECORDER PDF

These test methods are called “fire resistance” and are carried out in full scale. Importantly, this includes the release of thick toxic smoke, which kills more people than the fire does 1.

In the other end there is a fan creating a draft forcing the flames to propagate into the tunnel. Our stone wool ceiling products can be specified to meet the most stringent requirements with a maximum Flame Spread Index of 0 and a maximum E1624 Developed Index of 5. Principally, it concerns the prevention of injury to people but it also entails limiting the material and economic damage which is likely to ensue.

ASTM-E, –

All of these beneficial qualities of stonewool contribute to adding the critical moments needed to find safety in the event of a fire. With fires developing five to 10 times faster today than in the s, the safety of building occupants and first-responders depends overwhelmingly on how the building performs during a fire. Fire resistant ceiling products protect what matters most — people. Stone wool and metal ceiling products are not organic, meaning they do not promote the growth of mold or bacteria.

Nails, Spikes, and Staples. Looking for reference examples or a gallery of ceiling images? The building itself including its design, building elements, materials, interior fittings and furnishing. Even the surface linings of the walls, floor and ceiling close to the fire can ignite.

The building regulations are formulated on a national basis and vary between different countries. Fire testing methods are generally designed to simulate the different phases of the fire process. Register for a trial account.

They must only make a negligible contribution to the fire development and to the production of smoke. Are you sure you want to aatm the cart?